Skip to content
There is a system change taking place so some orders may not ship until Tuesday 2nd September. Thank you for your patience!
There is a system change taking place so some orders may not ship until Tuesday 2nd September. Thank you for your patience!

Adande Rear Engine Single Dual Temperature Drawer VCR1

Original price $10,879.70 - Original price $11,416.36
Original price
$10,879.70
$10,879.70 - $11,416.36
Current price $10,879.70
SKU VCR1.CW

The Adande VCR1 is a single, independently controlled refrigerated drawer with the refrigeration system positioned behind the storage bin, creating a narrower 878 mm-wide format for deeper equipment lines.

Key Features

  • Independent digital temperature control from +15°C to -22°C
  • 86 L across 1 standard-height drawer
  • GN storage: 4 × 1/1 GN pans at 100 mm deep or 6 × 1/1 GN pans at 65 mm deep
  • Insulated “hold the cold” drawer design with low-velocity cooling
  • Operates in ambient temperatures up to 40°C using R600a refrigerant
  • External drawer runners and removable bin support hygienic cleaning
  • Maximum drawer loading: 40 kg

Why Choose This Product

Choose the VCR1 when line width is constrained but additional depth is available. Moving the engine to the rear reduces cabinet width compared with side-engine models, making the VCR1 useful beneath deeper cooking suites or in layouts where every millimetre along the line matters.

Simply Hospitality Notes

The VCR1 solves a width problem by using more depth. Measure the full 885 mm cabinet depth, rear ventilation and service route—not just the 878 mm width. Heatshield variants still require an independent stand for powered, gas or plumbed equipment.

Product Guide

Select rollers for a lower undercounter installation or castors for easier movement. Solid worktops accept up to 45 kg; heatshield tops manage exposure from equipment above. Rear-engine models need their full depth and a clear ventilation/service plan, so verify the rear space before treating width alone as the deciding factor.

Brand Guide

About Adande: Adande pioneered insulated refrigerated drawers that can be independently set anywhere from chilled to frozen operation. The drawer format brings bulk ingredients to the point of use, while low-velocity cooling and the insulated bin help retain cold air, humidity and food quality when the drawer is opened. The range is particularly valuable in chef bases, preparation stations and space-constrained production lines where conventional upright or undercounter cabinets place ingredients further from the operator. Model selection should account for drawer capacity, engine position, overall height, top construction and the service access required around adjacent cooking equipment.

Product Details

The rear-engine layout delivers the same 86-litre standard drawer capacity and GN compatibility as Adande's full-height single-drawer systems in an 878 mm-wide, 885 mm-deep footprint. Variant selection covers roller or castor bases and solid-worktop or heatshield tops.

Variant Selection

ModelConfigurationDimensions / Weight
VCR1.CWStandard Castor (adjustable) / Solid Work Top878 x 885 x 502 / Shipping Weight: 133kg
VCR1.CHSStandard Castor (adjustable) / Heatshield Top878 x 885 x 545 / Shipping Weight: 144kg
VCR1.RWRoller (adjustable) / Cover Top878 x 885 x 429 / Shipping Weight: 133kg
VCR1.RHSRoller (adjustable) / Heatshield Top878 x 885 x 500 / Shipping Weight: 143kg
VCR1.HCHSHigh Castor / Heatshield Top878 x 885 x 624 / Shipping Weight: 146kg

Core Specifications

Model familyVCR1
Configurationrear-engine single drawer
Temperature range+15°C to -22°C
Capacity86 L
GN compatibility4 × 1/1 GN pans at 100 mm deep or 6 × 1/1 GN pans at 65 mm deep
Drawer load40 kg
Footprint878 × 885 mm
Electrical connection0.38 kW, 230 V, 10 A plug and lead
Declared energy usage1.19 kWh/24h chilled; 2.53 kWh/24h frozen
RefrigerantR600a
Climate classClass 4
Maximum ambient40°C
Warranty24 months parts and labour

Suitable Applications

  • Deep modular cooking lines
  • Narrower chef-base installations
  • Single-zone chilled or frozen point-of-use storage

Installation and Operation

Install the cabinet level, allowing no more than a 5 mm fall to the rear, and retain the ventilation and service clearances required for the selected configuration. Powered, gas, live-fuel or plumbed cooking equipment must not be installed directly on the drawer; use a suitable independent stand. Close drawers promptly during service to protect temperature stability and energy performance.

Technical Documents

CAD & BIM Files

  • Model 1. VCR1.RW - Roller/Solid Work Top, 2. VCR1.RHS - Roller/Heatshield Top, 3. VCR1.CW - Standard Castor/Solid Work Top, 4. VCR1.CHS - Standard Castor/Heatshield Top, 5. VCR1.HCHS - High Castor/Heatshield Top
  • Warranty If registered within 90 days of purchase - eligible for 5 Years Extended Parts Warranty (T&C’s apply). If not registered - 2 Years Parts & Labour
  • Power / Load 0.28kW / 10A plug & lead fitted